if the trx_off instruction is used in the "rf_status" register during rx_on, the rx_on state may remain in its state rather than becoming the trx_off state. if the force trx_off instruction is used, the rx_on state will shift to the trx_off state without any obstructions. what can be considered as a factor that makes the trx_off instruction ineffective during rx_on?
when the following dio mode is used, it is recognized that reception is in progress, so the action will continue even if the trx_off instruction is executed. therefore, in this mode, use the force_trx_off instruction to switch the state to trx_off. - constant output mode (rxdio_ctrl = 0b01) "constant reception in progress" is determined. to stop reception, issue the force_trx_off instruction. - data output mode 1 (rxdio_ctrl = 0b10) "reception in progress after detecting syncword" is determined. to stop reception, issue the force_trx_off instruction.
related products: ml7344/ml7406 family, ml7345 family, ml7404, ml7414